CombiDiagnost R90

Cross functional DRF system

Product number:

709030

This remote controlled fluoroscopy system in combination with high-end digital radiography is designed for consistent, superb image quality and high room utilization, in a cost effective manner.

This remote controlled fluoroscopy system in combination with high-end digital radiography is designed for consistent, superb image quality and high room utilization, in a cost effective manner.

Specifications Show all

Tube: SRM 0608 ROT GS 505
Maximum voltage
125 kV (110 kV in GCF)
Anode heat storage capacity
800 kHU (593kJ)
focal spot
0.6 /0.8
Geometry
Motorized compressor
3 kg - 15 kg (6.6 lbs - 33.1 lbs) compression force
Table height
62 cm - 142 cm (24.4"-59.9")
Maximum patient weight
284 kg (626 lbs) without limitations
Tube column movement range
160 cm (63")
Table tilt angle
-90°/+90°
Source to Image Distance (SID)
113 cm – 183 cm (44’’ to 72’’)
Generator
Fluoroscopy techniques
Pulsed fluoroscopy (PF), in-pulse controlled
Grid-controlled fluoroscopy (GCF), in-pulse controlled
Power
65 kW, 80kW optional
Tube voltage flouroscopy
40 - 125 kV
Tube voltage exposure
40 - 150 kV
Exposure techniques
Manual: kV-mAs or kV-mA-s
Automatic Exposure Control (AEC) - Intelligent Exporuse (IQX), In-Pulse controlled
Automatic kV reduction techniques
Ceiling Suspension
Ceiling height at SID 110 cm (44")
2.83 m to 3.21 m (8'8.3" - 10'5.9")
Collimator
Motorized, automatic
Type
Four-part telescopic column
Tube: SRO 33100 ROT380 (for CS)
Maximum voltage
150 kV
focal spot
0.6 /1.2
Anode heat storage capacity
300 kHU (200kJ)
Wireless detector: SkyPlate Large
Detector size
35 cm x 43 cm (14" x 17")
Image matrix size
2330 x 2846 pixel
Type
Digital Csl (Cesium Iodide) flat detector
Active area
34.48 cm x 42.12 cm (13.6" x 16.6")
Wireless detector: SkyPlate Small
Active area
22.2 cm x 28.4 cm (8.7" x 11.2")
Image matrix size
1500 x 1920 pixel
Type
Digital Csl (Cesium Iodide) flat detector
Detector size
24 cm x 30 cm (app. 10" x 12")
Tube: SRO 33100 ROT380
Anode heat storage capacity
300 kHU (200kJ)
Maximum voltage
150 kV
focal spot
0.6 /1.6
Digital vertical stand
Detector Size
SkyPlate detector
Motorized tilting
Optional, -20° to +90°
Vertical travel
30 cm - 180 cm (11.8" - 5'11")
Dynamic Flat Detector
Pixel size
148 µm
Acquisition mode continious fluoroscopy
Up to 30 frames per second
Acquisition mode pulsed fluoroscopy
Up to 20 per second
Image matrix size
2,874 pixel x 2,840 pixel
Detector Size
43 cm x 43 cm (17"x17")